Hybrid closed-loop insulin delivery versus sensor-augmented pump therapy in children aged 6–12 years: a randomised, controlled, cross-over, non-inferiority trial

Dulanjalee Kariyawasam
  • Fonction : Auteur
Carole Morin
  • Fonction : Auteur
Kristina Casteels
  • Fonction : Auteur
Claire Le Tallec
  • Fonction : Auteur
Annie Sfez
  • Fonction : Auteur
Cécile Godot
  • Fonction : Auteur
Erik Huneker
  • Fonction : Auteur
Nathalie Garrec
  • Fonction : Auteur
Michel Polak
  • Fonction : Auteur
Guillaume Charpentier
  • Fonction : Auteur
Sylvia Franc
  • Fonction : Auteur
Jacques Beltrand
  • Fonction : Auteur

Résumé

Background: Time in range (TIR) goals are rarely met in children with type 1 diabetes, except at the cost of increased hypoglycaemia episodes. Our objective was to evaluate the safety and efficiency of the Diabeloop DBL4K (Diabeloop, Grenoble, France) hybrid closed-loop system in prepubescent children. Methods: We did a multicentre, open-label, randomised, controlled, non-inferiority, two-session crossover study in the paediatric endocrinology departments of three university hospitals in France and Belgium. Eligible participants were aged 6-12 years with type 1 diabetes for at least 1 year, glycated haemoglobin A1C 9% (75 mmol/mol) or less, and insulin pump treatment for at least 3 months. Participants were randomly assigned (1:1) to a closed-loop device or sensor-augmented pump (open loop) therapy. Randomisation was by a permuted block randomisation scheme, using an interactive web-based response system, and was stratified on centre (block size 6). The assessed closed-loop device, the Diabeloop for Kids DBL4K hybrid closed-loop system, is an automated blood glucose regulation system composed of a handset, insulin pump, and continuous glucose monitor. The open-loop system is defined as a sensor-augmented pump therapy composed of the usual insulin pump used by the patient and a continuous glucose monitor. A 72-h in-patient period was followed by a 6-week home phase. After a 1-week washout period, the participants crossed over to the other device. The primary outcome, assessed in the intention-to-treat population, was the mean proportion of time spent in hypoglycaemia (3·9 mmol/L [<70 mg/dL]) during the hospital phase, with a non-inferiority margin of -2·5% (absolute value). Safety was assessed in the intention-to-treat population on a per-protocol basis. This study was registered with ClinicalTrials.gov, NCT03671915. Findings: Between May 6 and Dec 23, 2019, we included 21 participants (closed loop then open loop, n=10; open loop then closed loop, n=11). The proportion of time spent in hypoglycaemia was significantly lower with the closed-loop system than the open-loop system in both groups (2·04% [95% CI 0·44 to 3·64] vs 7·06% [5·46 to 8·66]; non-inferiority one-sided p<0·0001). No severe ketoacidosis, nor severe hyoglycaemic events or fatal adverse events occurred. All 25 adverse events (18 with the closed-loop system, seven with the open-loop system) were related to the treatment. Interpretation: The closed-loop Diabeloop system decreased hypoglycaemic episodes and provided good metabolic control in prepubescent children with type 1 diabetes, under real-life conditions. This finding supports the safe use of closed-loop technology in this paediatric population. Funding: Diabeloop. Translation: For the French translation of the abstract see Supplementary Materials section.

Dates et versions

hal-04554054 , version 1 (22-04-2024)

Identifiants

Citer

Dulanjalee Kariyawasam, Carole Morin, Kristina Casteels, Claire Le Tallec, Annie Sfez, et al.. Hybrid closed-loop insulin delivery versus sensor-augmented pump therapy in children aged 6–12 years: a randomised, controlled, cross-over, non-inferiority trial. The Lancet Digital Health, 2022, 4 (3), pp.e158-e168. ⟨10.1016/S2589-7500(21)00271-5⟩. ⟨hal-04554054⟩

Collections

UGA LBFA
3 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Mastodon Facebook X LinkedIn More